<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-14 07-43-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 55 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 69 kHz 17259 4,1428
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,8 dBr 4,04 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 10 kHz % above 76 kHz: 4,1428 Acquired: 2025/11/14 7.42.53 Total samples: 17259 Equivalent time: 0:14:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,1 dBr MIN: 1,8 dBr AVE: 4,04 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/11/14 7.42.53) 07.28 07.30 07.32 07.34 07.36 07.38 07.40 07.42 0 2 4 6 Pm [dBr]